Accident Report Detail
Accident: 200452175 - Employee Is Killed In Excavation Collapse
Accident: 200452175 -- Report ID: 0418600 -- Event Date: 11/20/2006 | |||||||
Inspection | Open Date | SIC | Establishment Name | ||||
---|---|---|---|---|---|---|---|
310509849 | 11/20/2006 | 1623 | P. F. Moon & Company, Inc. | ||||
On November 20, 2006, Employee #1 was demolishing a manhole at a water treatment plant. The nearly vertical face of the excavation was not scaled back and a protective system was not being used. Employee #1 was killed when he was struck by falling dirt and engulfed when the excavation face collapsed. | |||||||
Keywords:
excavation, collapse, work rules, trench, shoring, asphalt
| |||||||
End Use | Proj Type | Proj Cost | Stories | NonBldgHt | Fatality | ||
Sewer/water treatment plant | Alteration or rehabilitation | $5,000,000 to $20,000,000 | 1 | 30 | X | ||
Employee # | Inspection | Age | Sex | Degree | Nature | Occupation | Construction |
1 | 310509849 | Fatality | Cancer | Occupation not reported | FallDist: FallHt: Cause: Demolition FatCause: Wall (earthen) collapse |