Accident Report Detail
Accident: 200451169 - Employee Killed When Crane Load Line Strikes Power Line
Accident: 200451169 -- Report ID: 0418600 -- Event Date: 12/28/2001 | |||||||
Inspection | Open Date | SIC | Establishment Name | ||||
---|---|---|---|---|---|---|---|
304836083 | 12/28/2001 | 1622 | Mcinnis Corporation | ||||
On December 28, 2001, Employee #1 was disconnecting a "clothes pin" pile driving hammer from a crane load line when the load line contacted a 14,400- volt power line several times. Employee #1 was electrocuted. | |||||||
Keywords:
clearance, overhead power line, crane boom, work rules, electrocuted, struck against, suspended load, construction
| |||||||
End Use | Proj Type | Proj Cost | Stories | NonBldgHt | Fatality | ||
Bridge | Alteration or rehabilitation | $1,000,000 to $5,000,000 | X | ||||
Employee # | Inspection | Age | Sex | Degree | Nature | Occupation | Construction |
1 | 304836083 | Fatality | Electric Shock | Occupation not reported | FallDist: FallHt: Cause: Pile driving FatCause: Electrocution by equipment contacting wire |