Accident Report Detail
Accident: 200411049 - Two Employees Asphyxiated In Reactor
Accident: 200411049 -- Report ID: 0317300 -- Event Date: 11/05/2005 | |||||||
Inspection | Open Date | SIC | Establishment Name | ||||
---|---|---|---|---|---|---|---|
305948945 | 11/07/2005 | 8999 | Matrix Service Industrial Contractors, Inc. | ||||
Employees #1 and #2, two boilermakers, were working on top of a reactor which was being overhauled. The reactor was inerted with nitrogen. The employees were removing a roll of tape which had been left in the reactor. It is presumed that Employee #1 either fell or climbed into the reactor and then Employee #2 climbed in to rescue Employee #1. Both employees were killed. | |||||||
Keywords:
lung, asphyxiated, reactor, confined space, inhalation, gas, nitrogen
| |||||||
Employee # | Inspection | Age | Sex | Degree | Nature | Occupation | |
1 | 305948945 | Fatality | Asphyxia | Boilermakers | |||
2 | 305948945 | Fatality | Asphyxia | Boilermakers |