Accident: 200361889 - Employee Suffers Facial Burns When Sprayed With Degreaser

Accident: 200361889 -- Report ID: 0453710 -- Event Date: 09/03/2013
InspectionOpen DateSICEstablishment Name
31709017309/04/20132077Valley Proteins, Inc.
On September 3, 2013, Employee #1 was performing cleaning operations on evaporator #2 immediately adjacent to a grease house at the facility. The employee finished the first part of the cleaning operation where an industrial grade degreaser was introduced into the system. Employee #1 removed a hose from the water pump and the pressure in the hose caused the employee to lose control which resulted in Employee #1 being sprayed in the face with the degreaser and hot water mixture. Employee #1 was transported to an area hospital, where he was treated for facial burns and later released.
Keywords: burn, cleaning, degreaser, face, pressure release, hot water
Employee # Inspection Age Sex Degree Nature Occupation
1 317090173 Non Hospitalized injury Other Occupation not reported

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.