Accident Report Detail
Accident: 200203651 - Employee Is Killed When Crushed By Machinery
Accident: 200203651 -- Report ID: 0418200 -- Event Date: 05/12/2011 | |||||||
Inspection | Open Date | SIC | Establishment Name | ||||
---|---|---|---|---|---|---|---|
314641978 | 05/13/2011 | 3479 | First American Resources Company, Llc | ||||
On May 12, 2011, Employee #1 was working for an employer that specialized in the coating of coils. The coating machine used for this process consisted of several accumulators, ovens, and drive motors with idler rollers attached. While the machine was in operation, Employee #1 opened the machine's metal cage, designed to guard moving parts, to inspect the rollers of the machine. For an unknown reason, Employee #1 then reached into the machine, causing his hand to become caught by the moving parts. Employee #1's upper body was pulled into the machine, killing him. | |||||||
Keywords:
fracture, guard, machine operator, caught by, roller--mach/part, crushed, coating operation, hand
| |||||||
Employee # | Inspection | Age | Sex | Degree | Nature | Occupation | |
1 | 314641978 | Fatality | Amputation | Supervisors, production occupations |