Accident Report Detail
Accident: 200200939 - Employee Killed In Fall From Elevated Forklift Platform
Accident: 200200939 -- Report ID: 0418200 -- Event Date: 07/23/1999 | |||||||
Inspection | Open Date | SIC | Establishment Name | ||||
---|---|---|---|---|---|---|---|
302558705 | 07/26/1999 | 1731 | Westin Industries, Inc. | ||||
Employee #1 was working from an elevated work platform that consisted of an 18 in. by 30 in. board atop a 4 ft by 4 ft wood plank pallet that was mounted on the forks of a Genie Superlift material handler. He was sitting in a metal folding chair on the board and was being hoisted toward the ceiling by a coworker using a two-hand winch. Employee #1 was at a height of approximately 15 ft with the forks extended when he fell to the concrete floor and was killed. | |||||||
Keywords:
unsecured, work rules, construction, riding on equipment, industrial truck, fall, elevated work plat, work platform, work surface, unstable position
| |||||||
End Use | Proj Type | Proj Cost | Stories | NonBldgHt | Fatality | ||
Other building | Alteration or rehabilitation | $500,000 to $1,000,000 | 2 | X | |||
Employee # | Inspection | Age | Sex | Degree | Nature | Occupation | Construction |
1 | 302558705 | Fatality | Concussion | Occupation not reported | FallDist: FallHt:15 Cause: Interior plumbing, ducting, electrical work FatCause: Fall, other |