Accident: 200090066 - Employee Injured When Scissor Lift Overturns, Later Dies

Accident: 200090066 -- Report ID: 0112300 -- Event Date: 03/12/1997
InspectionOpen DateSICEstablishment Name
30009232703/12/19971721Capitol Painting Inc
Employee #1 was using a scissor lift to power wash the side of a building. He either tried to move the lift while it was extended and hit a depression in the concrete, or the lift was buffeted by strong winds. The lift tipped over and Employee #1 fell approximately 20 ft to the ground. He sustained head and internal injuries, from which he died later that night. There were no witnesses to this accident.
Keywords: head, high wind, work rules, construction, riding on equipment, fall, fall protection, work surface, aerial lift, overturn
End Use Proj Type Proj Cost Stories NonBldgHt Fatality
Manufacturing plant Maintenance or repair Under $50,000 1 20 X
Employee # Inspection Age Sex Degree Nature Occupation Construction
1 300092327 Fatality Fracture Occupation not reported FallDist:
FallHt:20
Cause: Exterior painting
FatCause: Fall from/with bucket (aerial lift/basket)

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.