Accident Report Detail
Accident: 200040335 - One Killed, Four Injured In Chemical Tank Explosion
Accident: 200040335 -- Report ID: 0653510 -- Event Date: 08/06/1999 | |||||||
Inspection | Open Date | SIC | Establishment Name | ||||
---|---|---|---|---|---|---|---|
302269360 | 08/10/1999 | 4952 | Professional Services Group Inc | ||||
On August 6, 1999, Employees #1 through #5 were present during a transfer operation involving sodium hypochlorite. A chemical reaction occurred between the sodium hypochlorite and an incompatible chemical, causing the tank to erupt. Employee #1 was killed. Employees #2 through #5 sustained injuries, for which Employees #2 and #3 were hospitalized. | |||||||
Keywords:
caustic, work rules, explosion, chemical reaction, chemical burn, skin, chemical vapor, tank, chemical
| |||||||
Employee # | Inspection | Age | Sex | Degree | Nature | Occupation | |
1 | 302269360 | Non Hospitalized injury | Burn(Chemical) | Water and sewage treatment plant operators | |||
2 | 302269360 | Hospitalized injury | Burn(Chemical) | Water and sewage treatment plant operators | |||
3 | 302269360 | Hospitalized injury | Burn(Chemical) | Water and sewage treatment plant operators | |||
4 | 302269360 | Fatality | Burn(Chemical) | Water and sewage treatment plant operators | |||
5 | 302269360 | Non Hospitalized injury | Bruise/Contus/Abras | Water and sewage treatment plant operators |