Powered by GoogleTranslate

Occupational Safety and Health Administration OSHA

Accident Report Detail

Accident: 200030773 - One Killed, One Injured When Lift Overturns Into River

Accident: 200030773 -- Report ID: 0521700 -- Event Date: 09/24/1999
InspectionOpen DateSICEstablishment Name
30311524009/24/19991611Baker Heavy & Highway, Inc.
Employees #1 and #2 were using an aerial lift situated a barge to strip forms from underneath a bridge over the Chicago River. The lift rolled off the barge and into the river, plunging both workers into the water. Employee #1 drowned and Employee #2 sustained serious injuries.
Keywords: barge, unsecured, work rules, construction, river, fall, drown, elevated work plat, aerial lift, overturn
End Use Proj Type Proj Cost Stories NonBldgHt Fatality
Highway, road, street New project or new addition $1,000,000 to $5,000,000 20 X
Employee # Inspection Age Sex Degree Nature Occupation Construction
1 303115240 Fatality Other Occupation not reported FallDist:
FallHt:20
Cause: Stripping and curing concrete
FatCause: Fall from/with bucket (aerial lift/basket)
2 303115240 Hospitalized injury Other Occupation not reported FallDist:
FallHt:20
Cause: Stripping and curing concrete
FatCause: Fall from/with bucket (aerial lift/basket)

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.