Accident: 200002939 - One Employee Is Killed, One Is Injured In Fall From Lift

Accident: 200002939 -- Report ID: 0728500 -- Event Date: 11/10/2009
InspectionOpen DateSICEstablishment Name
31340524311/10/20091791Midwest Steel, Inc.
On November 10, 2009, Employees #1 and #2, both iron workers, were working from an aerial lift, when the lift reportedly began behaving erratically and fell over. Employee #1 was killed and Employee #2 was seriously injured. Apparently, Employee #2's neck was fractured, and he was hospitalized. The JLG Model Number 1250AJP lift was brand new, with only 66 hours of engine use.
Keywords: fracture, construction, fall, neck, aerial lift, overturn
End Use Proj Type Proj Cost Stories NonBldgHt Fatality
Commercial building New project or new addition $5,000,000 to $20,000,000 10 125 X
Employee # Inspection Age Sex Degree Nature Occupation Construction
1 313405243 Fatality Concussion Construction trades, n.e.c. FallDist:
FallHt:75
Cause: Erecting structural steel
FatCause: Fall from/with bucket (aerial lift/basket)
2 313405243 Hospitalized injury Fracture Construction trades, n.e.c. FallDist:
FallHt:75
Cause: Erecting structural steel
FatCause: Fall from/with bucket (aerial lift/basket)

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.

Close