Accident: 200001238 - Electric Shock - Contact With Overhead Line Thru Pole

Accident: 200001238 -- Report ID: 0728500 -- Event Date: 04/19/2001
InspectionOpen DateSICEstablishment Name
30430062704/20/20011623Co-Mo Electric Cooperative, Inc.
A power line crew was replacing a utility pole. They were using a digger-derrick to set the new pole. The pole being replaced fell against the extended boom of the digger-derrick, energizing the truck and electrocuting an employee.
Keywords: digger-derrick, overhead power line, electrical, electrocuted, e ptd, elec utility work, lost control, utility pole
End Use Proj Type Proj Cost Stories NonBldgHt Fatality
Single family or duplex dwelling Alteration or rehabilitation Under $50,000 35 X
Employee # Inspection Age Sex Degree Nature Occupation Construction
1 304300627 Fatality Electric Shock Occupation not reported FallDist:
FallHt:
Cause: Interior plumbing, ducting, electrical work
FatCause: Electrocution by equipment contacting wire

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.