Accident: 171063340 - Employee Is Killed When Crushed By Equipment

Accident: 171063340 -- Report ID: 0854910 -- Event Date: 07/28/2003
InspectionOpen DateSICEstablishment Name
30360919207/28/20033949Lifetime Products
At around 11:55 p.m. on July 28, 2003, Employee #1, a maintenance worker with Lifetime Products, was found crushed under a pneumatic lift table which was under approximately 3500 PSI hydraulic pressure. The accident occurred in the robot cage, which is surrounded by a chain-link fence and a gate which was interlocked to shut down the robot while it was open. The robot was not running when the compliance officer arrived. In addition to the robot, the cage is surrounded a pneumatic lift table which is used to raise or lower stacks of products coming off the assembly line. The products, which were in cardboard boxes, were placed on the lift table by the robot. Once on the lift table, the products would be raised or lowered the correct location for a cardboard sleeve to be stapled to them. Evidence indicated that Employee #1 was working on the staplers. A box of staples and a set of Allen wrenches were located next to the lift table and staplers. One of the Allen wrenches was removed from the set and was laying on the floor next to where Employee #1 was found. This Allen wrench fit the adjustment screws on the staplers. A coworker stated that he heard the staple guns firing ten-round bursts within a few minutes of when the accident occurred, indicating that someone was working on the staplers. It was not determined during the inspection how the lift table was activated while Employee #1 was underneath it, but it apparently trapped him while he was attempting to exit the pit underneath the table. The medical examiners report indicates that Employee #1 died as a result of compressional asphyxia. A subsequent investigation was conducted by Lifetime Products. This investigation, dated August 4, 2003, indicated that the lift table may have been activated by the stapler linear slide being manually moved to the full retract position, triggering the limit switch. By triggering the limit switch, the table moved to the down position toward the bottom limit switch, trapping Employee #1.
Keywords: maintenance, asphyxiated, robot, crushed
Employee # Inspection Age Sex Degree Nature Occupation
1 303609192 Fatality Asphyxia Machinery maintenance occupations

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.

Close