Powered by GoogleTranslate

Occupational Safety and Health Administration OSHA

Accident Report Detail

Accident: 171005556 - Employee'S Eye Burned In Exothermic Explosion

Accident: 171005556 -- Report ID: 0950632 -- Event Date: 07/07/1994
InspectionOpen DateSICEstablishment Name
11999916707/20/19943672Toppan West Inc
Employee #1, of a printed circuit board manufacturer, was pouring liquid from a mislabeled drum. Ammonium hydroxide solution reacted with hydrogen peroxide and caused an exothermic reaction, resulting in the chemicals splashing into the face and eyes of Employee #1. He incurred some damage to his eye while he was flushing his eyes under an eyewash during the second of three explosions from the exothermic reaction. The exposure occurred in the water treatment area, where drums are rinsed prior to reuse or reclaiming. The explosive reaction occurred in a 5 gal bucket and the first of three explosions occurred within a few seconds after the ammonia-containing liquid entered the bucket containing 35 percent peroxide. The reuse of the peroxide-labeled drum was in direct violation of the employer's written safety program and Employee #1's eye protection also violated the employer's safety program. The employer's eyewash/shower was within 10 feet of the incident.
Keywords: eye, ppe, hydrogen peroxide, work rules, chemical reaction, chemical burn, struck by, face, chemical
Employee # Inspection Age Sex Degree Nature Occupation
1 119999167 Non Hospitalized injury Burn(Chemical) Separating, filtering & clarifying mach. operators

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.

Close