Accident Report Detail
Accident: 170831879 - Employee'S Leg Injured When Struck By Falling Crane Boom
Accident: 170831879 -- Report ID: 0352450 -- Event Date: 04/02/1996 | |||||||
Inspection | Open Date | SIC | Establishment Name | ||||
---|---|---|---|---|---|---|---|
127373975 | 04/02/1996 | 1761 | Korb Roofers, Inc | ||||
Employee #1 was directing the loading of roofing material by a National crane, model 875, serial #14764, that was mounted on a Mack truck chassis. At an angle of 23 degrees and a load weight of 2,530 lb, which was 630 lb over the maximum accountable weight, the turret separated from the mount and the boom collapsed. Employee #1 suffered a strained leg. He was evacuated by a helicopter to a shock/trauma unit in Baltimore, where he was treated and released with a brace for his leg. Employee #1's story has changed and medical opinions differed, so an exact determination of his injury and how it happened was not possible. | |||||||
Keywords:
collapse, crane boom, work rules, overloaded, construction, struck by, flying object, sprain, crane, leg
| |||||||
Employee # | Inspection | Age | Sex | Degree | Nature | Occupation | |
1 | 127373975 | Non Hospitalized injury | Strain/Sprain | Roofers |