Powered by GoogleTranslate

Occupational Safety and Health Administration OSHA

Accident Report Detail

Accident: 170764450 - Employee'S Fingertips Amputated In Chipper Conveyor

Accident: 170764450 -- Report ID: 0950615 -- Event Date: 06/19/1998
InspectionOpen DateSICEstablishment Name
12558607306/22/19982421Redwood Empire Aggregates
Employee #1 was clearing debris and trim and feeding it into a chipper conveyor at a sawmill. He was standing next to the machine's box chain drive motor, which was approximately 30 in. above the floor, when he began to clean away some debris from the V-belt without shutting down. His right hand became caught in the belt and pulley, amputating the tips of his middle and ring fingers that resulted in nail and bone loss. Neither the belt nor the pulley were guarded.
Keywords: amputated, finger, work rules, cleaning, conveyor, v-belt, nip point, pulley, unguarded
Employee # Inspection Age Sex Degree Nature Occupation
1 125586073 Non Hospitalized injury Amputation Laborers, except construction

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.