Powered by GoogleTranslate

Occupational Safety and Health Administration OSHA

Accident Report Detail

Accident: 170723050 - Uncertified Crane Tips Over, No Injuries

Accident: 170723050 -- Report ID: 0950623 -- Event Date: 04/22/1993
InspectionOpen DateSICEstablishment Name
11975626004/27/19931799Dunsmuir, City Of
The city of Dunsmuir hired an owner/operator crane service to set a new brush in place in the sewer treatment pond. The city did not ensure that the hired crane, a Bucyrus-Erie H-3 hydrocrane with a 5-ton capacity mounted on a Ford 750 truck, was certified. The brush being picked up weighed 2,500 pounds. The radius of the lift was 35 to 38 feet. The lift chart indicates that at 35 feet the crane, with outriggers fully extended, can successfully lift a load weighing as much as 1,800 pounds. This attempt, however, was being made without the outriggers fully extended and while the crane's weight capacity was exceeded. The crane tipped over.
Keywords: crane outrigger, work rules, suspended load, construction, crane
Employee # Inspection Age Sex Degree Nature
1 119756260

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.

Close