Accident: 170632863 - Employee'S Finger Lacerated In Punch Press

Accident: 170632863 -- Report ID: 0950644 -- Event Date: 10/16/1996
InspectionOpen DateSICEstablishment Name
12612120111/12/19963444Midwest Fabrications
At approximately 8:10 a.m. on October 16, 1996, Employee #1, a punch press operator at Mid-West Fabricating Company, was operating Toledo punch press #97 when her left index finger became caught in the point of operation action and was lacerated. The machine was equipped with pull-back restraints. Subsequent investigation revealed that the setup man had adjusted the right pull-back but not the left pull-back, thus enabling Employee #1's finger to remain in the point of operation.
Keywords: pull back device, finger, work rules, laceration, point of operation, set up, press operator, punch press, press
Employee # Inspection Age Sex Degree Nature Occupation
1 126121201 Hospitalized injury Amputation Punching and stamping press machine operators

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.