Accident: 170632400 - Employee'S Abdomen And Chest Lacerated By Portable Saw

Accident: 170632400 -- Report ID: 0950644 -- Event Date: 09/13/1996
InspectionOpen DateSICEstablishment Name
12612124311/15/19961522D.T. Synder Co.
Employee #1, of the D.T. Snyder Company, was using a Skil HD-77 portable, power driven, circular hand saw to notch a 2 by 4 for framing. The saw blade struck a knot and the saw kicked back into Employee #1. He sustained a deep laceration to his abdomen and chest, for which he was hospitalized. The guard had a nail in it, rendering it inoperative.
Keywords: chest, kick back, portable power tool, abdomen, guard, work rules, construction, circular saw, laceration, struck by
Employee # Inspection Age Sex Degree Nature Occupation
1 126121243 Hospitalized injury Cut/Laceration Carpenters

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.