Accident: 170630149 - Six Employees Burned When Sawdust Explodes

Accident: 170630149 -- Report ID: 0950642 -- Event Date: 09/29/1995
InspectionOpen DateSICEstablishment Name
11987455009/29/19955211Saroyan Lumber Co
At approximately 9:45 p.m. on September 29, 1995, Employees #1 through #6, of Saroyan Lumber, were coming from lunch break together in a group. As they were walking by the containment room, where a hatch is opened to dump sawdust on the floor, an explosion occurred and a huge ball of fire engulfed the six employees. All six sustained first-, second-,and third-degree burns on their bodies, faces, arms, and legs. They were taken to Sherman Oaks Burn Center. Employees #1, #2, and #3 are still in the hospital with Employee #2 listed in critical condition. Employees #4, #5, and #6 are being treated as outpatients.
Keywords: burn, sawdust, fire, torso, explosion, arm, combustible dust, face, leg
Employee # Inspection Age Sex Degree Nature Occupation
1 119874550 Non Hospitalized injury Burn/Scald(Heat) Occupation not reported
2 119874550 Hospitalized injury Burn/Scald(Heat) Occupation not reported
3 119874550 Hospitalized injury Burn/Scald(Heat) Occupation not reported
4 119874550 Hospitalized injury Burn/Scald(Heat) Occupation not reported
5 119874550 Non Hospitalized injury Burn/Scald(Heat) Occupation not reported
6 119874550 Non Hospitalized injury Burn/Scald(Heat) Occupation not reported

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.