Accident: 170571731 - Employee Killed When Crushed By Carriage In Film Coater

Accident: 170571731 -- Report ID: 0454510 -- Event Date: 08/08/1996
InspectionOpen DateSICEstablishment Name
12649653808/14/19963083Rexam Corporation
Employee #1 was operating a Faustel film coating machine when the film backwrapped around a roll under a moveable carriage, jamming the machine. Employee #1 hit the emergency STOP button and then climbed behind the moveable carriage to unjam the film. The carriage moved and crushed Employee #1's abdomen against the accumulator frame. He sustained injuries that required hospitalization.
Keywords: abdomen, work rules, emergency stop, jammed, lockout, caught between, crushed, coating operation
Employee # Inspection Age Sex Degree Nature Occupation
1 126496538 Hospitalized injury Other Industrial engineers

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.