Powered by GoogleTranslate

Occupational Safety and Health Administration OSHA

Accident Report Detail

Accident: 170570337 - Employee Injured When Struck By Boom

Accident: 170570337 -- Report ID: 0454510 -- Event Date: 08/06/1996
InspectionOpen DateSICEstablishment Name
12650011508/12/19961791Schwab & Sage Building Copr.
Employee #1, a steelworker, was in an area where a truck crane was being used to raise a bolted-together steel structure just enough to insert wedges on the bottom of a column. The boom was at a 56 degree angle when it buckled and collapsed, striking Employee #1. He sustained injuries that required hospitalization. At that angle, the maximum weight the boom could handle was 3,800 lb; the weight being lifted was estimated by independent engineers to be over 12,000 lb.
Keywords: boom, collapse, crane boom, truck crane, work rules, overloaded, construction, struck by
Employee # Inspection Age Sex Degree Nature Occupation
1 126500115 Hospitalized injury Other Structural metal workers

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.

Close