Accident: 170245526 - Employee'S Toe Amputated In Ice Auger

Accident: 170245526 -- Report ID: 1055310 -- Event Date: 05/25/1990
InspectionOpen DateSICEstablishment Name
11157069305/25/19902091Shannon Point Seafoods Inc
At approximately 4:45 p.m. on May 25, 1990, Employee #1 and two coworkers were cleaning out the ice house. Employee #1 was in front of the ice house, one coworker was in back of the ice house, and another coworker was on the dock outside the ice house. Employee #1 and one coworker were stomping ice chunks into a 12 in. ice auger that was covered by a grate made of 3/4 in. rebar with 2 in. (inside) openings, except where two of the grate sections met, leaving an opening of 3 1/2 in. During the stomping of the ice chunks, the toe of Employee #1's shoe slipped through this opening and contacted the ice auger. The little toe of his right foot was amputated. The two coworkers helped Employee #1 get his foot out of the auger. Employee #1 required hospitalization.
Keywords: amputated, cleaning, slip, grating, auger, floor opening, toe, foot
Employee # Inspection Age Sex Degree Nature Occupation
1 111570693 Hospitalized injury Amputation Occupation not reported

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.

Close