Accident: 170238604 - Employee Killed In Fall From Aerial Platform

Accident: 170238604 -- Report ID: 1055310 -- Event Date: 03/22/1999
InspectionOpen DateSICEstablishment Name
11532235603/23/19993721Bf Goodrich Aerospace Mro Group Inc
Employee #1 was using a manually propelled elevating aerial platform to access an aircraft when he fell and was killed. The platform was not designed for this purpose. The guardrails installed were sloped and only 30 to 31 in. high, which was too low to provide adequate protection. A significant gap was left between the aircraft fuselage and the guardrail.
Keywords: aircraft, guardrail, work rules, fall, elevated work plat, work platform, aerial lift
Employee # Inspection Age Sex Degree Nature Occupation
1 115322356 Fatality Bruise/Contus/Abras Occupation not reported

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.