Accident: 170218218 - Logger Crushed And Killed By Falling Tree

Accident: 170218218 -- Report ID: 0552652 -- Event Date: 03/23/1994
InspectionOpen DateSICEstablishment Name
12491610703/24/19942411Bruce Brzoznowski Logging Inc
On March 23, 1994, Employee #1 was felling a tree at a logging site. He improperly cut his notch and lost his hinge wood, which controls the direction of the tree fall. When Employee #1 made his back cut, the tree twisted as it started to fall. It came completely loose from the stump and struck him in the chest, killing him. A citation was issued for a serious violation of 5156(2) and 5118(4).
Keywords: chest, tree felling, work rules, crushed, tree, struck by, falling object, logging
Employee # Inspection Age Sex Degree Nature Occupation
1 124916107 Fatality Fracture Occupation not reported

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.