Accident Report Detail
Accident: 170210694 - Employee Dies Of Asphyxia In Oxygen Deficient Manhole
Accident: 170210694 -- Report ID: 0552651 -- Event Date: 09/17/1993 | |||||||
Inspection | Open Date | SIC | Establishment Name | ||||
---|---|---|---|---|---|---|---|
114834930 | 09/20/1993 | 1623 | Dans Excavating Inc | ||||
On September 17, 1993, Employee #1, of Dan's Excavating Inc., a laborer on a sewer construction crew, entered a 26 ft deep manhole to check the line sight glass for water levels. After he had climbed to the bottom of the manhole, Employee #1 made a noise as if he were clearing his throat and then started climbing back out. When Employee #1 was 6 to 8 ft from the top he looked up, let go of the ladder, and fell backward to the bottom of the manhole. Employee #1 died of asphyxia. The atmosphere had not been tested before he entered the manhole. When it was later tested at the manhole level from which Employee #1 fell, an oxygen deficiency was found. Citations were issued for serious violations of R408.40121(1), R408.40121(2), and R408.41115(8). | |||||||
Keywords:
oxygen deficiency, asphyxiated, confined space, work rules, construction, manhole
| |||||||
Employee # | Inspection | Age | Sex | Degree | Nature | Occupation | |
1 | 114834930 | Fatality | Amputation | Occupation not reported |