Powered by GoogleTranslate

Occupational Safety and Health Administration OSHA

Accident Report Detail

Accident: 170203210 - Employee Struck By Rope While Using Rail Car Puller

Accident: 170203210 -- Report ID: 0950626 -- Event Date: 06/10/1990
InspectionOpen DateSICEstablishment Name
11194111807/09/19902819Imperial West Chemical
Employee #1 was using a rope on a capstan-type railroad car puller to move a loaded chlorine rail car that had rolled off the end of a rail siding. Employee #1 was pulling on the tail of a rope that was attached to the rail car. He was standing a few feet from the rotating car puller. The 1 1/2 in. diameter polypropylene rope was wrapped twice around the Stevens Adamson Inc. car puller driven by a 10 HP Allis Chalmers motor. The capstan of the car puller was 12 in. in diameter and 9 in. high. The rope became crossed on the capstan, resulting in loss of control by the employee. The rope was incorrectly rigged. Employee #1 was struck by the rope and suffered a fractured right lower leg and foot.
Keywords: fracture, rope, railroad car, struck by, flying object, lost control, winch, foot, leg
Employee # Inspection Age Sex Degree Nature Occupation
1 111941118 Hospitalized injury Fracture Miscellaneous plant and system operators

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.

Close