Accident: 170193361 - Employee Crushed And Killed In Batch Mixer

Accident: 170193361 -- Report ID: 0950633 -- Event Date: 08/08/1991
InspectionOpen DateSICEstablishment Name
11201410508/08/19913273Tru-Cast Concrete Products Inc
At approximately 4:10 p.m. on August. 8, 1991, Employee #1, of Tru-cast Concrete Products, Inc., Corona, CA, was assigned to clean a batch mixing machine on a raised platform in Department #31. When he entered the machine, the main switch and disconnect had not been locked out. A gust of wind blew the access door shut, energizing a switch on the access door that stops the machine when the door is opened. The mixing machine started and Employee #1 was crushed and killed.
Keywords: high wind, work rules, cleaning, mixer, concrete mixer, lockout, crushed
Employee # Inspection Age Sex Degree Nature Occupation
1 112014105 Fatality Other Mixing and blending machine operators

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.