Powered by GoogleTranslate

Occupational Safety and Health Administration OSHA

Accident Report Detail

Accident: 170156244 - Employee'S Finger Amputated By Screw Conveyor

Accident: 170156244 -- Report ID: 0950642 -- Event Date: 03/18/1992
InspectionOpen DateSICEstablishment Name
11215862103/19/19922011Clougherty Packing Llc Dba / Farmer John
Employee #1, the assistant foreman of the rendering department of Clougherty Packing Co., was working on the night shift when he noticed grease pouring from the bottom of the trough covering the bottom of a screw conveyor. The conveyor transported grease and solids into a rendering vat. The conveyor was located over a grease pit, below the surface of the concrete floor; thus, it was difficult to check the bottom of the trough by sight. When Employee #1 felt the bottom of the trough, his glove was caught by the moving screw, and his right index finger was pulled in and amputated.
Keywords: maintenance, amputated, screw conveyor, finger, glove, caught by, conveyor, blind reaching
Employee # Inspection Age Sex Degree Nature Occupation
1 112158621 Hospitalized injury Amputation Miscellaneous plant and system operators

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.

Close