Accident Report Detail
Accident: 170153845 - Employee Killed Inside Retort
Accident: 170153845 -- Report ID: 0950641 -- Event Date: 10/15/1990 | |||||||
Inspection | Open Date | SIC | Establishment Name | ||||
---|---|---|---|---|---|---|---|
112113048 | 10/15/1990 | 1400 | Pb Metals | ||||
At approximately 5:00 p.m. on October 15, 1990, Employee #1, a supervisor for Metals Division of Paul R. Briles, Inc., entered a 35 in. diameter by 59 1/2 in. deep retort through its open top to weld and clean its bottom. At approximately 9:05 p.m., he was found inside the retort, slumped down and not breathing. Employee #1was killed. The retort was normally used to heat-treat titanium wire and bolts with argon gas. A copy of the coroner's report was requested. | |||||||
Keywords:
unconsciousness, confined space, ppe, work rules, cleaning, inhalation, welding, argon
| |||||||
Employee # | Inspection | Age | Sex | Degree | Nature | Occupation | |
1 | 112113048 | Fatality | Asphyxia | Management related occupations, n.e.c. |