Accident: 170151013 - Employee Burned In Benzoyl Peroxide Explosion

Accident: 170151013 -- Report ID: 0950643 -- Event Date: 12/20/1994
InspectionOpen DateSICEstablishment Name
12007301001/03/19957812Crypt Keeper Pictures
Employee #1 was a special effects pyrotechnician in the movie industry, working on a miniature pyrotechnical job for Cryptkeeper Pictures in the 10-ton special effects truck on the movie set. He was preparing a dummy that was to be blown-up during the movie. Employee #2 was in the special effects truck putting away a roll of tape that Employee #1 had needed to prepare the dummy. Employee #1 was going to use 1/4 lb of dry benzoyl peroxide as an explosive. The benzoyl peroxide was packaged in a paper pouch with a non-conductive plastic liner, and was stored in an ice chest. Employee #1 took out the pouch and put it in a plastic bag. He then repaired a carved-out area on the dummy that had been made for explosives, but that had been broken. He used a glue called Zap-a-Gap, or Hot Stuff, to repair the breaks in the carved-out area, then placed the pouch inside and taped it in. Employee #1 had just turned around when the benzoyl peroxide exploded. He suffered second- and third-degree burns, primarily on his back and left arm. Employee #2 was about 6 to 8 ft away from the explosion, and suffered a light burn, similar to sunburn, on the back of his right hand and both sides of the face. Employee #1 later stated that the heat generated by the glue hardening may have caused the benzoyl peroxide to ignite and explode.
Keywords: burn, heat, explosives, repair, back, explosion, chemical reaction, arm, combustible dust, chemical
Employee # Inspection Age Sex Degree Nature Occupation
1 120073010 Hospitalized injury Burn/Scald(Heat) Technicians, n.e.c.
2 120073010 Non Hospitalized injury Burn/Scald(Heat) Technicians, n.e.c.

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.

Close