Accident: 170107528 - Employee'S Finger Amputated In Power Press

Accident: 170107528 -- Report ID: 0551800 -- Event Date: 11/06/1991
InspectionOpen DateSICEstablishment Name
10855978211/19/19913564Stewart Manufacturing Company
At about 3:30 p.m. on November 6, 1991, Employee #1 was operating a #7 Federal full-revolution mechanical power press, serial #7-227. The employee deactivated the dual palm button trip and reached into the unguarded die to remove the part. The press cycled and amputated his right index finger. The press's cylinder shaft was later found to have been scored by vise grip pliers. The scoring damaged the seals, causing leakage that allowed the press to inadvertently cycle.
Keywords: leak, amputated, cylinder, power press, finger, two-hand control, press operator, mech malfunction, unguarded
Employee # Inspection Age Sex Degree Nature Occupation
1 108559782 Hospitalized injury Amputation Punching and stamping press machine operators

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.