Powered by GoogleTranslate

Occupational Safety and Health Administration OSHA

Accident Report Detail

Accident: 170100192 - Struck By Overhead Communications Line

Accident: 170100192 -- Report ID: 1055320 -- Event Date: 10/21/1994
InspectionOpen DateSICEstablishment Name
11548247310/21/19944813Gte Northwest Inc
A telephone company crew responded to an automobile accident involving a utility pole. One of the employees on the crew was assigned to control traffic on the east side of the worksite. Meanwhile, the other crew members replaced the damaged pole and began to reattach the communications line to the pole. As the line was being brought up to the new pole, it came loose two poles away. The line segment swung out into the road and struck employee controlling traffic in the back of the neck. He died of his injuries at the scene.
Keywords: telecom work, communication cable, equipment failure, neck, struck by, communication worker
Employee # Inspection Age Sex Degree Nature Occupation
1 115482473 Fatality Other Telephone line installers and repairers

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.

Close