Accident: 170061485 - Employee Suffers Severe Laceration To Tip Of Right Fingers
Accident: 170061485 -- Report ID: 0453710 -- Event Date: 12/04/1995 | |||||||
Inspection | Open Date | SIC | Establishment Name | ||||
---|---|---|---|---|---|---|---|
125304048 | 01/23/1996 | 3499 | Sunline Usa Group Inc | ||||
Employee #1 was operating a full revolution punch press (L&J model W60) when she reached into the point of operation to remove a part and was struck on the right index fingertip. Employee #1 sustained a severe laceration to the finger. Investigation determined that a cotter pin had failed, causing the release lever rod (anti-repeat mechanism) to fall out. This cotter pin failure caused the press to cycle continuously. The 2-hand control was located too close to the point of operation and allowed the operator to reach into the point of operation before the press downstroke had been completed. | |||||||
Keywords:
finger, cotter pin, equipment failure, laceration, point of operation, struck by, punch press, mech malfunction
| |||||||
Employee # | Inspection | Age | Sex | Degree | Nature | Occupation | |
1 | 125304048 | Non Hospitalized injury | Cut/Laceration | Punching and stamping press machine operators |