Accident Report Detail
Accident: 170060891 - Employee'S Hand Amputated In Punch Press
Accident: 170060891 -- Report ID: 0453710 -- Event Date: 02/13/1995 | |||||||
Inspection | Open Date | SIC | Establishment Name | ||||
---|---|---|---|---|---|---|---|
125248674 | 03/27/1995 | 3613 | General Electric Company | ||||
Employee #1 was setting up a 75 ton repetitive action press. He reached around a light curtain into the die and activated the press by contacting a foot pedal, amputating his hand. There were no side guards on the press. | |||||||
Keywords:
die, amputated, work rules, foot control, lockout, set up, light curtain, punch press, hand, unguarded
| |||||||
Employee # | Inspection | Age | Sex | Degree | Nature | Occupation | |
1 | 125248674 | Hospitalized injury | Amputation | Punching and stamping press machine operators |