Accident: 170054175 - One Employee Killed And One Injured By Argon

Accident: 170054175 -- Report ID: 0453710 -- Event Date: 01/12/1993
InspectionOpen DateSICEstablishment Name
1854681201/13/19933711Freightliner Truck Manufacturing Co.
Employees #1 and #2 were using supplied air respirators while spray painting trucks. The pipes providing air to the respirators had inadvertently been hooked to a 100 percent argon gas line intended for welding. Employee #1 was killed. Employee #2 was affected by the inhalation. The spray booth had been newly installed over the Christmas holidays.
Keywords: oxygen deficiency, inhalation, spray painting, argon, inattention, respirator
Employee # Inspection Age Sex Degree Nature Occupation
1 18546812 Non Hospitalized injury Asphyxia Painting and paint spraying machine operators
2 18546812 Fatality Asphyxia Painting and paint spraying machine operators

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.