Accident: 170044176 - Employee Killed When Crushed Between Granite Slabs And Wall

Accident: 170044176 -- Report ID: 1055320 -- Event Date: 11/22/1996
InspectionOpen DateSICEstablishment Name
11527792311/22/19961741Michael E Homchick Dba Masonry Construction
At 7:44 a.m. on November 22, 1996, Employee #1 was removing a 2 by 4 wood crib that held 5 ft 7 in. by 10 ft sheets of granite upright on the 5 ft 7 in. edge. Employee #1 did not wait for a coworker to arrive with bar clamps to secure the sheets, but he used a reciprocating saw to cut through two of the vertical 2 by 4 members of the crib. Eleven of the 800 lb sheets fell toward Employee #1, pinning his chest against the wall of the trailer in which they were loaded. He died of asphyxia.
Keywords: chest, asphyxiated, unsecured, pinned, work rules, construction, crushed, off loading, struck by
Employee # Inspection Age Sex Degree Nature Occupation
1 115277923 Fatality Asphyxia Occupation not reported

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.