Accident Report Detail
Accident: 14568216 - Employee'S Hand Amputated In Molding Machine
Accident: 14568216 -- Report ID: 0454510 -- Event Date: 01/05/1987 | |||||||
Inspection | Open Date | SIC | Establishment Name | ||||
---|---|---|---|---|---|---|---|
105434823 | 01/13/1987 | 3089 | Sewell Plastics Inc. | ||||
EMPLOYEE #1 WAS CLEANING A NISSEI STRETCH BLOW MOLDING MACHINE, TYPE A5B6 50 EXII, SERIAL NUMBER 866 53 56, LOCATED IN THE MOLDING INJECTION DEPARTMENT. THE MACHINE CYCLED AND CAUGHT EMPLOYEE #1'S RIGHT HAND, PULLING IT INTO THE MACHINE. THE EMPLOYEE SUFFERED A PARTIAL AMPUTATION OF HIS RIGHT HAND (LEAVING THE THUMB AND SOME PALM). THE MACHINE DOOR WAS EQUIPPED WITH AN INTERLOCK, BUT IT HAD BEEN BYPASSED WITH A JUMPER WIRE. | |||||||
Keywords:
amputated, molding machine, work rules, cleaning, caught by, interlock, lockout, hand
| |||||||
Employee # | Inspection | Age | Sex | Degree | Nature | Occupation | |
1 | 105434823 | Hospitalized injury | Amputation | Extruding and forming machine operators |