Accident Report Detail
Accident: 14545669 - Employee Dies After Being Severely Burned In Explosion
Accident: 14545669 -- Report ID: 0418300 -- Event Date: 08/08/1990 | |||||||
Inspection | Open Date | SIC | Establishment Name | ||||
---|---|---|---|---|---|---|---|
106232770 | 08/08/1990 | 5093 | Scrapco, Inc. | ||||
On August 7, 1990, Employee #1 was cutting the frame of a scrap box car into pieces with a cutting torch. He cut into the center sill of a cushion unit. The unit expanded and blew apart, spraying oil on the employee. The oil ignited, setting the employee's clothes on fire. He sustained 3rd-degree burns over 75 percent of his body. Employee #1 died on August 20, 1990. | |||||||
Keywords:
burn, clothing, fire, torch, explosion, cutting and burning
| |||||||
Employee # | Inspection | Age | Sex | Degree | Nature | Occupation | |
1 | 106232770 | Fatality | Burn/Scald(Heat) | Occupation not reported |