Accident: 14534895 - Employee Killed In Unprotected Fall From Building'S Edge

Accident: 14534895 -- Report ID: 0931300 -- Event Date: 05/09/1989
InspectionOpen DateSICEstablishment Name
10001397805/11/19891522Sammi Rock Products, Inc.
InspectionOpen DateSICEstablishment Name
10288641308/17/19891522Sammi Rock Products, Inc.
Employee #1 and a coworker were tying rebar for a concrete pour on the roof of a 7 story building within 2 ft of the building's edge. A guardrail had been erected around the perimeter of the building; the midrail was 33 in. high. When Employee #1 had completed a tie and moved to begin another, he apparently tripped or somehow lost his balance. He slipped under the guardrail and fell 70 ft to his death. Had the midrail been erected at 21 in. or had Employee #1 been wearing a safety belt that was tied off to the structure, the fall might have been prevented. Weather did not appear to be a contributing factor. No one saw Employee #1 fall.
Keywords: guardrail, work rules, safety belt, slip, construction, fall, lost balance, tie-off
Employee # Inspection Age Sex Degree Nature Occupation
1 100013978 Fatality Other Occupation not reported
2 102886413 Occupation Not Listed

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.

Close