Accident Report Detail
Accident: 14528699 - Severe Laceration To Finger From Hydraulic Punch Press
Accident: 14528699 -- Report ID: 0111700 -- Event Date: 03/09/1984 | |||||||
Inspection | Open Date | SIC | Establishment Name | ||||
---|---|---|---|---|---|---|---|
1819101 | 05/02/1984 | 3069 | Bellofram Corporation | ||||
A HYDRAULIC PUNCH PRESS OPERATOR SUSTAINED A SEVERE LACERATION (AMPUTATION) TO A FINGER THAT WAS IN THE DIE AREA WHEN THE TOP PART OF THE DIE CAME DOWN ON THE FINGER. THE PRESS HAD TWO HAND CONTROLS AND ALLOWED HANDS IN THE DIE TO LOAD THE WORK PIECE. RUBBER PARTS WERE BEING TRIMMED BY THE PRESS. WHAT APPARENTLY OCCURRED WAS THAT THE SAFETY DEVICE USED TO CATCH THE UPPER PART OF DIE FROM DROPPING ON THE FINGERS EITHER FAILED OR WAS NOT ADJUSTED CORRECTLY. THE DIE DROPPED BECAUSE THE VERTICAL SHAFT IN THE HYDRAULIC CYLINDER BROKE. ON EACH SHIFT THE PRESS MAINTENANCE MAN IS SUPPOSED TO CHECK THE DIE SAFETY DEVICES FOR PROPER POSITIONING . THIS ACCIDENT ACCUMULATED AT LEAST 82 LOST DAYS AT THE TIME OF INSPECTION. | |||||||
Keywords:
die, amputated, die safety device, finger, two-hand control, punch press, press
| |||||||
Employee # | Inspection | Age | Sex | Degree | Nature | Occupation | |
1 | 1819101 | Non Hospitalized injury | Cut/Laceration | Punching and stamping press machine operators |