Accident: 14514152 - Employee Killed When Struck On Head By Crane Hook Block

Accident: 14514152 -- Report ID: 0524700 -- Event Date: 04/05/1990
InspectionOpen DateSICEstablishment Name
11029398204/06/19903312Empire Detroit Steel
InspectionOpen DateSICEstablishment Name
11029399004/06/19904731Triangle Equipment Corporation
At 9:00 a.m. on April 5, 1990, Employee #1, of Triangle Equipment Corp., a trucking company, was working at Empire Detroit Steel when a two-blocked crane hook block, which did not have a hoist upper travel safety limit switch, jammed and severed the lift cables. The block fell on the employee's head, killing him.
Keywords: head, two-blocking, hoisting mechanism, broken cable, struck by, crane block, falling object, limit switch
Employee # Inspection Age Sex Degree Nature Occupation
1 110293982 Fatality Other Occupation not reported
2 110293990 Occupation Not Listed

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.