Powered by GoogleTranslate

Occupational Safety and Health Administration OSHA

Alert: Due to routine maintenance on the OSHA website, some pages may be temporarily unavailable.
To report an emergency, file a complaint with OSHA or ask a safety and health question, call 1-800-321-6742 (OSHA).

Accident Report Detail

Accident: 14511125 - Ammonia Pressure Vessel Ruptured, Releasing Ammonia Gas

Accident: 14511125 -- Report ID: 0625400 -- Event Date: 05/29/1985
InspectionOpen DateSICEstablishment Name
191466205/30/19852097Southern Henke Ice Co
A PRESSURE VESSEL IN AN AMMONIA REFRIGERATOR SYSTEM RUPTURED UNDER PRESSURE OF 170 PSI. THE EXPLOSION CAUSED EXTENSIVE PHYSICAL DAMAGE AND RELEASED DENSE CLOUDS OF AMMONIA GAS. EMPLOYEES #1 THROUGH 4 DIED OF ACUTE AMMONIA INHALATION.
Keywords: ammonia, pressure vessel, inhalation, rupture, explosion, high pressure
Employee # Inspection Age Sex Degree Nature Occupation
1 1914662 Fatality Asphyxia Occupation not reported
2 1914662 Fatality Asphyxia Occupation not reported
3 1914662 Fatality Asphyxia Occupation not reported
4 1914662 Fatality Asphyxia Occupation not reported

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.

Close