Accident: 14508527 - Employee Asphyxiated In Corn Barge

Accident: 14508527 -- Report ID: 0316110 -- Event Date: 09/11/1984
InspectionOpen DateSICEstablishment Name
184875309/11/19844491Continental Grain Company
InspectionOpen DateSICEstablishment Name
184876109/11/19841711J & J Sheet Metal Co Inc
Some employees were unloading a 195-ft by 135-ft grain barge at a Norfolk, VA grain elevator. This barge had been loaded with 20 to 21 percent moist yellow field corn on September 1, 1984, at an Elizabeth City, NC grain elevator. It traveled via tug to Norfolk on September 4, 1984. On September 11, 1984, at approximately 3:30 am, an employee entered the aft starboard personnel hatch on the barge to retrieve a rope. Only the center hatch cover (1 of 12 covers) was removed. The employee entered the barge without using a ladder or flashlight. He had conducted no atmospheric tests before entry. Within 1 to 2 minutes after entry, the employee called for help. He lost consciousness, landed face down in the corn, and was asphyxiated. Four other employees entered the barge without respiratory protection and were transported to, and treated at, a local hospital. Subsequent atmospheric tests taken 7 to 8 hours later, after the barge had been open for 3 to 4 hours, did not reveal an oxygen deficient atmosphere or any toxic substances.
Keywords: asphyxiated, compartment, barge, confined space, grain, hatch, corn
Employee # Inspection Age Sex Degree Nature Occupation
1 1848753 Hospitalized injury Asphyxia Occupation not reported
2 1848753 Hospitalized injury Asphyxia Occupation not reported
3 1848753 Fatality Asphyxia Occupation not reported
4 1848753 Hospitalized injury Asphyxia Occupation not reported
5 1848761 Hospitalized injury Asphyxia Occupation not reported

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.