Accident: 14500482 - Employee Crushed Between Shuttle Arm And Machine Frame

Accident: 14500482 -- Report ID: 0523400 -- Event Date: 01/28/1991
InspectionOpen DateSICEstablishment Name
10234807501/29/19913714Daimler Chrysler Corp.
At approximately 7:40 p.m. on January 28, 1991, Employee #1 was troubleshooting an automotive engine cylinder head transfer line. A heat treat machine was located adjacent to, and worked in conjunction with, the transfer line. The cylinder head transfer line advanced heads into the Tocco-Lamb heat treat machine (s/n 7120122). A cyclic problem developed with the heat treat machine, which stopped the transfer line feed through a limit switch that senses the advancement, or lack thereof, of the heads. Employee #1, a set-up person, swung open a hinged (non-interlocked) gate to the transfer line shuttle area, leaned in, and moved a cylinder head away from the limit switch. Since the electro-hydraulic energy source to the transfer shuttle line was still energized, it caused the shuttle to shift to the right. Employee #1's head was crushed between the shuttle arm and the machine frame, a space that diminished from 17 to 3 3/4 inches wide. The causal factor was inadvertent machine startup during a servicing function.
Keywords: head, maintenance, cylinder, work rules, lockout, caught between, crushed, machine--misc
Employee # Inspection Age Sex Degree Nature Occupation
1 102348075 Fatality Fracture Machinery maintenance occupations

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.

Close