Powered by GoogleTranslate

Occupational Safety and Health Administration OSHA

Accident Report Detail

Accident: 14498166 - Employee Killed When Struck By Falling Crane Block

Accident: 14498166 -- Report ID: 0626600 -- Event Date: 09/20/1985
InspectionOpen DateSICEstablishment Name
229994909/23/19851629H B Zachry Co
Employee #1 was approximately 25 ft away from where a crane operator was using an HSP 25 Link Belt hydraulic tire-mounted crane, model 19080, to move a 600 lb pipe from a structure to a place outside a fence. While he was scooping out with the jib, the main block was drawn tight up to the boom (two-blocking) and the line snapped. The lower block fell on Employee #1, killing him. The operator said he had been watching his flagman and his load. The last time he looked at his block, he had approximately 1 ft of rope and he thought that was enough to continue putting the pipe down.
Keywords: work rules, jib crane, broken cable, construction, struck by, two-blocking, crane block, falling object, hydraulic crane, inattention
Employee # Inspection Age Sex Degree Nature Occupation
1 2299949 Fatality Fracture Occupation not reported

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.

Close