Accident: 14479638 - Employees Injured After Falling From Roof

Accident: 14479638 -- Report ID: 0352440 -- Event Date: 08/08/1994
InspectionOpen DateSICEstablishment Name
11952469208/12/19941761Jack'S Roofing Company, Incorporated
InspectionOpen DateSICEstablishment Name
11952470008/16/19945033The Roof Center, Inc.
Employees #1 through #3, including two weather proof mechanics and one materials handler, were working approximately 35 feet above the ground on a 12:12 pitched church roof. The employees were standing on 2 by 10 boards that were supported by adjustable roofing brackets, unloading a pallet of slate shingles, when one of the roofing brackets failed. The employees slid off the roof and hit the ground. Employee #1 landed on a chain link fence and suffered severe lacerations to his right hand. Employee #2 landed on a grassy area in an adjoining back yard; he broke both legs and fractured his back. Employee #3 landed on the concrete sidewalk at the base of an access ladder; he sustained head contusions and scrapes and bruises. None of the employees were wearing safety harnesses and lanyards.
Keywords: roof bracket, work rules, equipment failure, lanyard, off loading, contusion, roof, construction, fall, fall protection
Employee # Inspection Age Sex Degree Nature Occupation
1 119524692 Hospitalized injury Cut/Laceration Roofers
2 119524692 Hospitalized injury Fracture Roofers
3 119524700 Hospitalized injury Fracture Helpers, construction trades

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.