InspectionOpen DateSICEstablishment Name
1805757012/02/19872821Cyro Industries
Employees #1 was shutting down an acrylic sheet manufacturing machine while operating the calendar rolls. A rotary joint supplied water to roll #2 at 88 degrees C and a pressure of 180 psi. The joint fractured, releasing the hot water. Employee #1 tried to run free of the area, but suffered second-degree burns on the right side of his face, arm, and back. The fracture was due to poor rotary joint design; the manufacturer is redesigning the rotary joint.
Keywords: burn, equipment failure, back, high pressure, arm, face, accidental discharge, high temperature, hot water, water
Employee # Inspection Age Sex Degree Nature Occupation
1 18057570 Hospitalized injury Burn/Scald(Heat) Occupation not reported

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.