Accident: 14471445 - Employee Killed When Crushed By Elevator

Accident: 14471445 -- Report ID: 0524200 -- Event Date: 01/09/1992
InspectionOpen DateSICEstablishment Name
10346418601/09/19921796U.S. Elevator Corporation
Employee #1 and a coworker were performing maintenance work on an elevator. Employee #1 was in the elevator pit standing on a ladder. The coworker was on the floor of the landing outside the elevator. Employee #1 closed the pit access doors to clean them. This caused the electrical circuit to close, which energized the elevator car. The car descended into the pit and crushed Employee #1. He was killed.
Keywords: maintenance, work rules, cleaning, construction, lockout, crushed, pit, elevator
Employee # Inspection Age Sex Degree Nature Occupation
1 103464186 Fatality Fracture Occupation not reported

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.