Accident: 14466494 - Employee Killed By Piece Of Broken Grinding Wheel

Accident: 14466494 -- Report ID: 0626300 -- Event Date: 06/09/1987
InspectionOpen DateSICEstablishment Name
10070125906/10/19873443C. E. Air Preheater Company - Q - Dot
Employee #1 was using an air-powered portable right-angle grinder with a 0.25-in.-thick, Type 27 specialty grinding wheel. He was cutting through a spot weld to separate two 4-in.-wide steel beams so that holes could be drilled in them. Employee #1 was leaning over the beam, holding the grinder in a vertical position, when the grinding wheel broke. A section of the wheel struck him in the chest, killing him. The grinder was not equipped with a safety guard. The model and brand of the grinder were not marked and were not known.
Keywords: chest, grinder, portable power tool, work rules, equipment failure, struck by, flying object, grinding wheel, unguarded
Employee # Inspection Age Sex Degree Nature Occupation
1 100701259 Fatality Cut/Laceration Occupation not reported

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.