Powered by GoogleTranslate

Occupational Safety and Health Administration OSHA

Accident Report Detail

Accident: 14460513 - Employee'S Finger Injured When Caught In Punch Press

Accident: 14460513 -- Report ID: 0352420 -- Event Date: 03/22/1984
InspectionOpen DateSICEstablishment Name
1484361905/09/19843564Air Techniques Inc
Employee #1 was punching out 50 pre-filter covers on an American Machinery electric mechanical punch press. When he released the foot pedal, the ram came down and caught his left index finger in the point of operation between the upper and lower dies. Employee #1 and his employer agreed that company training had advised the use of 10 in. screwdriver stock in addition to the operator's hands. The full-revolution clutch machine did not have point of operation guarding or an anti-repeat device.
Keywords: finger, work rules, caught between, point of operation, foot-powered press, press operator, punch press, unguarded
Employee # Inspection Age Sex Degree Nature Occupation
1 14843619 Hospitalized injury Amputation Administrators, protective services

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.